Affordable generator services and maintenance plans

Maximize your generator’s lifespan and minimize downtime with our comprehensive maintenance services. Regular generator maintenance is a smart investment that prevents costly breakdowns and keeps your equipment running at peak performance. We recommend scheduling a major service every six months, after 400 hours of operation, or at least once a year. These major services should be paired with routine preventative maintenance inspections to identify and address potential issues early. Neglecting regular maintenance can result in excessive wear, unexpected breakdowns, and significantly higher operating costs.

In addition to preventative care, we provide expert generator repair services to quickly and efficiently restore your equipment if issues arise. Whether it’s routine maintenance or urgent repairs, our team is dedicated to keeping your generator in optimal condition, so you can focus on what matters most.

Extend your generator’s lifespan and reduce downtime with our proactive maintenance plans and services.
Schedule major servicing every six months or every 400 hours, Along with regular inspections, to avoid costly breakdowns and repairs.
We also provide expert generator repair services to keep your equipment running smoothly.

Maintenance inspection Plans Saving You Time and Money in the Long Run

Maintenance inspection plans can prevent unexpected breakdowns, which can lead to costly repairs and downtime. By adhering to a maintenance schedule, potential issues can be identified and addressed early, extending the life of the generator.

Rely on our thorough diagnostic assessments to address any issues before they become major problems, thereby increasing efficiency and reducing future repair costs

Enjoy peace of mind with regular maintenance inspections that prevent unexpected breakdowns and keep your generator compliant with safety regulations.

Customized maintenance plans tailored to your operational needs ensure maximum efficiency and minimal downtime for your generator.

Uninterrupted Power: Our Comprehensive Generator Services Explained

We offer a complete service that covers everything from oil changes to fluid replacements, to visual Inspections and safety checks, ensuring your equipment operates at peak efficiency.

Generator Complete Service:(Engine, Alternator & Controls).

  • Change lubrication oil.
  • Replace oil filter and inspect base.
  • Replace spark plugs (except for diesel units). 
  • Inspect ignition coil wires and plug caps. 
  • Inspect cooling system, clean fins (air-cooled),top off radiator. 
  • Inspect fan guard for condition and security. 
  • Inspect and clean air filter and pre-cleaner. 
  • Replace fuel filters (diesel and gasoline). 
  • Inspect engine gaskets, breathers and fuel regulation components for any fuel or oil leakage.
  • Inspect and adjust engine belts, hoses and clamps. 
  • Lubricate governor and carburetor linkage. 
  • Load test battery and record VDC readings. 
  • Service battery, add water to electrolyte and clean posts. 
  • Check and record battery static and running charging rates 
  • Inspect engine and battery heaters for proper operation 
  • Inspect engine and electrical safety shutdown devices 
  • Inspect unit for excessive noise or vibrations 
  • Inspect mounting bolts, brackets and coupling connections 
  • Check, calibrate and record AC output Voltage & Frequency 
  • Inspect engine, alternator and control wiring
  • Inspect and clear dampers, louvers and air intakes 
  • Wipe down outside of generator and engine 

Automatic Transfer Switch 

  • Inspect for overheated power terminals and lugs 
  • Inspect control board wiring and connections 
  • Inspect mechanical switchgear mechanism
  • Additional Generator Services 
  • Replace engine battery(as needed).
  • Replace internal fuel hose (as needed). 
  • Adjust exhaust and intake valves (as needed, *mechanical valves only).
  • Replace ATS battery (as needed, if applicable).
  • Cooling system service (as needed, * liquid-cooled generators only). 
  • Perform power outage simulation w/ permission (as needed)
  • Check time delays (as needed).
  • Check and adjust exercise clock setting (as needed).
  • Replace battery terminals (as needed).
Generator Inspection Checklist
  • Check for visible damage, loose parts, or corrosion.
  • Ensure no oil, fuel, or coolant leaks.
  • Verify exhaust system is intact and unobstructed.
  • Check fuel levels.
  • Inspect fuel lines for leaks.
  • Check oil levels and top up as needed.
  • Inspect inspect radiator and hoses. for leaks and top up water and coolant if necessary.
  • Check cooling fan and belts for proper condition.
  • Clean or replace air filters; ensure air intakes are clear.
  • Inspect battery terminals; test battery under load.
  • Check wiring, fuses, and connectors for damage.
  • Test gauges, indicators, and startup/shutdown processes.
  • Check for error codes or warning lights.
  • Inspect for leaks or noise; ensure vents are unobstructed.
  • Run generator to test performance and stability under load.
  • Test automatic transfer switch (if applicable).
  • Update maintenance logs; schedule follow-up as needed.

This checklist keeps your generator efficient, reliable, and safe.

Engine, Alternator & Controls:

  • Change oil and replace oil filter.
  • Inspect ignition components, cooling system, and fan guard.

  • Clean or replace air filter.

  • Replace fuel filters and inspect for leaks.

  • Adjust belts, hoses, clamps, and lubricate linkages.

  • Test and service battery; record voltage readings.

  • Inspect heaters, shutdown devices, and for noise/vibrations

  • Check mounting hardware and calibrate AC output.

  • Inspect wiring, air intakes, and clean external surfaces.

 

Automatic Transfer Switch (ATS):

  • Inspect terminals, wiring, and switchgear.

Additional Services (As Needed):

  • Replace engine or ATS battery and fuel hoses.
  • Adjust valves (mechanical only) and perform cooling system service.
  • Simulate power outages, adjust time delays, and exercise clock.
  • Replace battery terminals.
Generator Inspection Checklist
  • Inspect for visible damage, loose parts, or leaks.
  • Check fuel, oil, and coolant levels; top up as needed.
  • Verify exhaust system, radiator, hoses, and belts are in good condition.
  • Clean/replace air filters; ensure clear air intakes.
  • Inspect battery, wiring, fuses, and connectors.
  • Test gauges, indicators, and startup/shutdown processes.
  • Run generator under load; test transfer switch if applicable.
  • Update logs and schedule follow-ups.